Pharma-Vac 
Performance Series 	
Purpose-built for pharmacy, medication, and vaccine, laboratory, and life science applications 
to support meeting CDC/VFC vaccine storage guidelines

Leader of cutting edge technology / Pride of LOTTE ENGINEERING & MACHINERY MFG is more than usual
| Model | LGB-F136RC | LGB-F166RC | LGB-F206RC | LGB-F256RC | LGB-F306RC | LGB-F366RC | |
|---|---|---|---|---|---|---|---|
| Gas Type | LNG | ||||||
| Heating Water Type | Air Closed Type | ||||||
| Heat Output | 15.1KW (13,000 Kcal/h)  | 
											18.6KW (16,000 Kcal/h)  | 
											23.3KW (20,000 Kcal/h)  | 
											29.1KW (25,000 Kcal/h)  | 
											34.9KW (30,000 Kcal/h)  | 
											41.9KW (36,000 Kcal/h)  | 
										|
| Hot Water Output | 18.6KW (13,000 Kcal/h)  | 
											18.6KW (13,000 Kcal/h)  | 
											23.3KW (20,000 Kcal/h)  | 
											34.9KW (30,000 Kcal/h)  | 
											34.9KW (30,000 Kcal/h)  | 
											41.9KW (36,000 Kcal/h)  | 
										|
| Hot Water Capacity | △T30℃ | 8.9 L/min | 8.9 L/min | 11.1 L/min | 16.7 L/min | 16.7 L/min | 24.0 L/min | 
| △T40℃ | 6.7 L/min | 6.7 L/min | 8.3 L/min | 12.5 L/min | 12.5 L/min | 15 L/min | |
| Heating efficiency(Full Load)(LNG(%) | 83.8% | 82.8% | 83.4% | 83.4% | 81.4% | 84.6% | |
| Heating efficiency(Partial load)(LNG%) | 86.3% | 86.8% | 87.3% | 85.9% | 86.1% | 84.6% | |
| D.H.W Efficiency(LNG %) | 83.0% | 83.0% | 83.5% | 81.5% | 82.0% | ||
| Smokestak Diameter | Air supply hole | Ø 75 mm | |||||
| Ventilation | Ø 75 mm | ||||||
| Hot water minimum using pressure | 19.5kPa (0.2kgf/㎠) | ||||||
| Heating maximum using pressure | 294kPa (3.0kgf/㎠) | ||||||
| Gas inlet supply pressure | 1.0~2.5kPa(100~250mmH2O) | ||||||
| Capacity expansion tank | 8 L | ||||||
| Temperature range of heating water | 40℃ ~ 80℃ | ||||||
| Voltage / Frequency | AC 220V / 50 Hz, 60 Hz | ||||||
| Dimension(H x D x W) | 600 x 230 x 450 | 600x230x500 | |||||
| Weight | Net | 24.5kg | 24.5kg | 25.3kg | 27.0kg | 27.0kg | 31kg | 
| Gross | 28kg | 28kg | 29kg | 31kg | 31kg | 34kg | |
| Loading Qty (20FT/40FT) | 195 / 420 | ||||||
| Model | LGB-F136RO | LGB-F166RO | LGB-F206RO | LGB-F256RO | LGB-F306RO | LGB-F366RO | |
|---|---|---|---|---|---|---|---|
| Gas Type | LNG | ||||||
| Heating Water Type | Air Open Type | ||||||
| Heat Output | 15.1KW (13,000 Kcal/h)  | 
											18.6KW (16,000 Kcal/h)  | 
											23.3KW (20,000 Kcal/h)  | 
											29.1KW (25,000 Kcal/h)  | 
											34.9KW (30,000 Kcal/h)  | 
											41.9KW (36,000 Kcal/h)  | 
										|
| Hot Water Output | 18.6KW (13,000 Kcal/h)  | 
											18.6KW (13,000 Kcal/h)  | 
											23.3KW (20,000 Kcal/h)  | 
											34.9KW (30,000 Kcal/h)  | 
											34.9KW (30,000 Kcal/h)  | 
											41.9KW (36,000 Kcal/h)  | 
										|
| Hot Water Capacity | △T30℃ | 8.9 L/min | 8.9 L/min | 11.1 L/min | 16.7 L/min | 16.7 L/min | 24.0 L/min | 
| △T40℃ | 6.7 L/min | 6.7 L/min | 8.3 L/min | 12.5 L/min | 12.5 L/min | 15 L/min | |
| Heating efficiency(Full Load)(LNG(%) | 83.8% | 82.8% | 83.7% | 83.3% | 81.5% | ||
| Heating efficiency(Partial load)(LNG%) | 85.9% | 85.9% | 87.5% | 85.5% | 85.5% | ||
| D.H.W Efficiency(LNG %) | 83.0% | 83.0% | 84.0% | 81.5% | 82.0% | ||
| Smokestak Diameter | Air supply hole | Ø 75 mm | |||||
| Ventilation | Ø 75 mm | ||||||
| Hot water minimum using pressure | 19.5kPa (0.2kgf/㎠) | ||||||
| Heating maximum using pressure | 98kPa (1.0kgf/㎠) | ||||||
| Gas inlet supply pressure | 1.0~2.5kPa(100~250mmH2O) | ||||||
| Capacity expansion tank | 8 L | ||||||
| Temperature range of heating water | 40℃ ~ 80℃ | ||||||
| Voltage / Frequency | AC 220V / 50 Hz, 60 Hz | ||||||
| Dimension(H x D x W) | 600 x 230 x 450 | 600x230x500 | |||||
| Weight | Net | 19.2kg | 19.2kg | 20.2kg | 21.8kg | 21.8kg | 31kg | 
| Gross | 22.2kg | 22.2kg | 23.2kg | 24.8kg | 24.8kg | 34kg | |
| Loading Qty (20FT/40FT) | 195 / 420 | ||||||