Go Contents

Pharma-Vac
Performance Series

Purpose-built for pharmacy, medication, and vaccine, laboratory, and life science applications
to support meeting CDC/VFC vaccine storage guidelines

Home > Product > Boiler

Gas Boiler | Condensing

Leader of cutting edge technology / Pride of LOTTE ENGINEERING & MACHINERY MFG is more than usual

Oh-k Condensing

Specification
Specification
Model LGB-F166CO LGB-F206CO
USE HEATING / DOMESTIC HOT WATER (COMBI)
EXHAUST TYPE FORCE FLUE (FF) / FAN EXHAUST
INTALLATION TYPE WALL-HANGING
HEATING WATER CIRCULATION AIR OPEN/CLOSED TYPE
HEATING
OUT PUT
CONDENSING kW(Kcal/h) 20.1kW(17,300kcal/h) 25.0kW(21,500kcal/h)
NORMAL kW(Kcal/h) 18.6kW(16,000kcal/h) 23.3kW(20,000kcal/h)
D.H.W. OUTPUT kW(Kcal/h) 18.6kW(16,000kcal/h) 23.3kW(20,000kcal/h)
D.H.W.
SUPPLY
CAPABILITY
△T30°C ℓ/min 8.9ℓ/min 11.1ℓ/min
△T40°C ℓ/min 6.7ℓ/min 18.3ℓ/min
GAS CONSUMPTION kW(Kcal/h) 21.4kW(18,400kcal/h) 26.7kW(23,000kcal/h)
HEATING EFFICIENCY LNG(%) 94.4% 94.5%
D.H.W. EFFICIENCY LNG(%) 88.5% 87.4%
D.H.W. MIN WORKING PRESSURE 0.2kgf/㎠(19.6kPa)
HEATING MAX WORKING PRESSURE 98 kPa (1.0kgf/㎤)
CONNECTION PIPE
DIAMETER
GAS JOINT PT 1/2"(15A)
HEATING WATER JOINT PT 3/4"(20A)
DIRECT/ HOT WATER PT 1/2"(15A)
GAS PRESSURE LNG 1.0 ~ 2.5 kPa (100 ~ 250mmH2O)
SIZE (mm) 680(H)*470(W)*250(D)
WEIGHT (kg) 23 24